Our legendary OC2 series has been revamped with improved features and was launched in June 2002.
Click Here for Flyer
OC2B is an open/closed chassis motor control that has been designed as building block solid state regulated power unit. OC2B uses state of the art control circuitry which can be used by itself, by wiring in the provided speed potentiometer as a straightforward speed regulated control or can be incorporated into much more sophisticated system designs contactor operation, external speed programming and tach feedback etc.
|
 |
|
|
 |
 |
 |
 |
|
 |
 |
 |
|
XLT7 Series
200V Class
Rated Input Voltage: 1/4
- 3 HP
200 - 240VAC, +10%,
Single or Three Phase (1Ø or 3Ø)
50/60Hz + 5%.
5 - 10 HP
200 - 240VAC, +10%,
3Ø (only)
50/60Hz + 5%.
Rated
Output Voltage:
200 - 240V + 10%, 3Ø
Corresponding to supply voltage.
XLT7
Series 230V
Model Selection Table |
| HP |
Model |
kW |
kVA |
Output (A) |
| 1/4 |
XLT7-03 |
0.2 |
0.6 |
1.4 |
| 1/2 |
XLT7-05 |
0.4 |
1.0 |
2.6 |
| 1 |
XLT7-10 |
0.75 |
1.6 |
4 |
| 2 |
XLT7-20 |
1.5 |
3.3 |
7.1 |
| 3 |
XLT7-30 |
2.2 |
4.5 |
10 |
| 5 |
XLT7-50 |
3.7 |
7.2 |
15.9 |
| 7.5 |
XLT7-75 |
5.5 |
9.1 |
24 |
| 10 |
XLT7-100 |
7.5 |
12.2 |
32 |
400V Class
Rated Input Voltage:
380 - 460VAC, +10%,
3Ø (only)
50/60Hz + 5%.
Rated Output Voltage:
380 - 460V + 10%, 3Ø
Corresponding to supply voltage.
XLT7 Series 460V
Model Selection Table
|
| HP |
Model |
kW |
kVA |
Output (A) |
| 1/2 |
XLT7-051 |
0.4 |
1.1 |
1.5 |
| 1 |
XLT7-11 |
0.75 |
1.9 |
2.5 |
| 2 |
XLT7-21 |
1.5 |
3.0 |
3.8 |
| 3 |
XLT7-31 |
2.2 |
4.3 |
5.5 |
| 5 |
XLT7-51 |
4.0 |
6.8 |
8.6 |
| 7.5 |
XLT7-76 |
5.5 |
10.4 |
13 |
| 10 |
XLT7-101 |
7.5 |
12.7 |
16 |
Control Method:
Sine-wavepulse
width modulation(PWM) control
Output Frequency Range:
0.5 - 360 Hz
To operate the beyond 50/60 Hz,
consult the motor manufacturer
about the maximum allowable speed
Frequency Accuracy:
Digital command:
+ 0.01% of the max. frequency
Analog command:
+ 0.2% (25°C + 10°C) of the max. frequency
Frequency Setting Resolution:
Digital:
0.1 Hz
Analog:
Max. frequency/1000
Volt./Freq. Characteristics:
Setting available for constant torque, reduced torque.
Overload Current Rating:
150%, 60 Seconds
Acceleration/Deceleration Time:
0.1 ~ 3000 sec. (linear/curve, accel./decel.),
Second stage accel./decel. setting available
Braking:
Dynamic Braking
(short time)-
Approx. 100%: up to 1 HP
Approx. 70%: >1 HP & < 3 HP
Approx. 20%: > 3 HP
The braking torque at capacitive feedback is the average deceleration
torque at the shortest deceleration (stoppage from 50/60 Hz)
of the motor itself. It is not the continuous regenerative
braking torque. And the average deceleration torque varies
with motor loss. This value decreases when operating beyond
50/60 Hz. If a large regeneration torque is required, the
optional braking resistor should be used.
DC Braking -
Operating frequency, time and braking force variable.
Input Signal:
Frequency Setting -
Digital Operator Panel:
Up(1) and Down(2) keys/value setting keys.
Potentiometer:
Analog Setting
External signal:
0 ~ 10 VDC (input impedence 10k ohms),
4 ~ 20 mA (input impedence 250k ohms)
Potentiometer: 1k to 2k ohms, variable resistor
The frequency command is the maximum frequency at 9.8V for
input voltage 0 - 10 VDC, or at 19.6 mA for input current
4 ~ 20 mA. If this characteristic is not convenient,
contact Polyspede.
Forward/Reverse/Run -
Digital Operator Panel:
Run/Stop (Forward/Reverse run change by command)
External signal:
Forward RUN/STOP (1a contact)
Reverse operation command available at terminal assignment
(1a/1b selectable)
Intelligent Input Terminals -
FW (Forward run command), RV (reverse run command, CF1~CF4
(multi-stage speed setting), JG (jogging command), 2CH (2-stage
acceleration/deceleration command), FRS (free run stop command),
EXT (external trip), USP (USP function), SFT (soft lock),
AT (analog current input select signal), RS (reset), PTC (thermal
protection).
Output Signal:
Intelligent Output Terminal -
RUN (running signal), FA1,2 (frequency arrival signal),
OL (overload advance notice signal),
OD (deviation signal at PID control), AL (alarm signal)
Frequency Monitor -
PWM output: Select analog output frequency monitor,
analog output current monitor or digital output frequency monitor
Alarm Output Contact:
ON for the inverter alarm (1C contact output) (possible to change to OFF for the alarm)
Other Functions:
AVR function, upper/lower limiter, PID control,
carrier frequency change, frequency jump, electronic thermal level adjustment, gain/bias setting function, retry function
Protective Function:
Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal
communication error.
Environmental Conditions:
Ambient Operating:
-10 ~ 50^(o)C
Storage Temperature: -10
~ 70^(o)C
Humidity: 20 ~ 90 % RH (no condensation)
Vibration: 5.9 m/s^(2) (0.6G),
10 ~ 55 Hz
Location:Less than 1000 m of altitude or less, indoors (no corrosive gases or dust)
Color:
Blue
Protective Structure:
IP20 (NEMA 1)
Options (cost extra):
Remote operator unit, copy unit, cables for the units, Dynamic braking unit, braking resistor, AC reactor, DC reactor, noise filter
FEATURES:
- World class, UL, CUL, TICK, CE (with noise filter)
- Communications using SC-OPE option (RS422, RS485)
- Compact size saves space
- Advanced functions
- PID control provide
- 16-stage multispeed operation
- Instantaneous power failure retry (frequency stabilization)
- Intelligent terminal system allows you to select only the necessary functions from the full lineup of enhanced functions
- Grouped functions for easy settings
- DC braking
- Two separately adjustable times for acceleration and two for deceleration
- Linear or S curve acceleration and deceleration
|
|
|
 |
Volts/Hertz, Sensorless
Vector and Flux Vector
drives ranging
from 1/4 to 200 HP.
|
 |
Non Regenerative
and Regenerative
drives from 1/6
to 500 HP.
|
 |
AC motors from Baldor,
AO Smith, Lincoln,
Marathon and Reliance.
|
 |
DC motors from Baldor
and AO Smith.
|
 |
|
| |
|