Our legendary OC2 series has been revamped with improved features and was launched in June 2002.
Click Here for Flyer 

OC2B is an open/closed chassis motor control that has been designed as building block solid state regulated power unit. OC2B uses state of the art control circuitry which can be used by itself, by wiring in the provided speed potentiometer as a straightforward speed regulated control or can be incorporated into much more sophisticated system designs contactor operation, external speed programming and tach feedback etc.


SC Series

The SC control is flexible, cost effective way to implement compact mini systems for manual or automatic motion control.  
It combines the popular OC2 control design with standard options and logic circuits.The SC series is available in three basic types:

    BSC for forward operation without armature contactors
    FSC for forward operation with one armature contactor
    RSC for forward and reverse operation with two armature contactors and dynamic braking

Ratings:

1/8 - 1 HP

Input:115 VAC + 10%, 1Ø, 50/60Hz + 5%
Output: 0-90 VDC armature, 100VDC field

1/4 - 5 HP

Input:  230 VAC + 10%, 1Ø, 50/60Hz + 5%
Output: 0-180 VDC armature, 200VDC field

 

 

Overload Capacity:
150% for one minute

Acceleration:
Adjustable from 0.5 to 15 seconds.

Torque (current) limit:
Adjustable from 50 to 150% of rating.

Minimum speed:
Adjustable from -5 to 10%

Maximum speed:
Adjustable from 70 to 110%

IR Compensation:
Adjustable from 0 to 10% boost.

FEATURES:
* Short circuit protection by sub-cycle line fuses.
* Independent, simultaneously operating torque and speed loops with sharp/smooth transition provide optimum speed regulation and precise torque limit cut-in regardless of speed setting.
* External torque limit program terminals can be used to set maximum torque in speed program mode or to program torque for tension control.
* Low level logic for options interfacing
* Screw type input-output connections
* Dynamic braking (standard on RSC, optional on FSC)
* Pushbutton start-stop operation
* Adjustable jog (optional)
* Automatic reversing (optional on RSC only)
* Voltage follower/isolator (optional)
* Multiple preset speeds (optional)
* NEMA 12 enclosure (optional)
* Speed meter (optional)
* Local operator station (optional)
* Remote operator Station (optional) 
* Tachometer feedback (optional)

SC Series Model Selection Table
HP Input BSC Model FSC Model RSC Model
1/8 115 VAC BSC-12 FSC-12 RSC-12
1/6 115 VAC BSC-16 FSC-16 RSC-16
1/4 115 VAC BSC-25 FSC-25 RSC-25
1/4 230 VAC BSC-26 FSC-26 RSC-26
1/3 115 VAC BSC-33 FSC-33 RSC-33
1/3 230 VAC BSC-34 FSC-34 RSC-34
1/2 115 VAC BSC-50 FSC-50 RSC-50
1/2 230 VAC BSC-51 FSC-51 RSC-51
3/4 115 VAC BSC-75 FSC-75 RSC-75
3/4 230 VAC BSC-76 FSC-76 RSC-76
1 115 VAC BSC-100 FSC-100 RSC-100
1 230 VAC BSC-101 FSC-101 RSC-101
1.5 230 VAC BSC-150 FSC-150 RSC-150
2 230 VAC BSC-200 FSC-200 RSC-200
3 230 VAC BSC-300 FSC-300 RSC-300
5 230 VAC BSC-500 FSC-500 RSC-500

OPTIONS LIST (cost extra)

Option

Notes

Code

Adjustable Jog  See Note I Independent of run speed

J2

Dynamic Braking Optional for FSC, standard for RSC

D

Automatic Reversing

RSC only

AR

Tach Feedback
50 VDC/1000 rpm Tach
(R) when used with RSC

1150 rpm motor

T(R)l

1750 rpm motor

T(R)2

2400 rpm motor

T(R)3

External Signal Controls
with isolators for input
signal.

1-5 mA DC

S11

4-20 mA DC

S12

10-50 mA DC

S13

0-6 VDC

S21

0-90 VDC (armature)

S31

0-180 VDC (armature

S32

0-240 VDC (armature)

S33

0-500 VDC (armature)

S34

0-20 VDC (tach)

S41

0-40 VDC (tach)

S42

0-80 VDC (tach)

S43

0-150 VDC (tach)

S44

Tach Follower
(no isolator)

 

0-20 VDC

TF1

20-65 VDC or 25-75VAC

TF2

65-200 VDC or75-200VAC

TF3

Preset Speeds - See Note 2  

 

7 internal

PS7

6 internal, I external

PS6

4 internal

PS4

3 internal, I external

PS3

7 external

PSO

10 turn Potentiometer and Dial

 

TPD

NEMA 12 Enclosure

with OFF/ON & Pilot Light

N12

Speed Meter

Installed on N12 option

SMI

Local Operator Control Station (installed on N12 option)

 

 

Start, Stop, Run-Jog, Speed Adjust

LOC-1

Start, Stop, Run-Jog, Manual/Auto, Speed Adjust

LOC-2

Start, Stop, Run-Jog, Fwd/Rev, Speed Adjust

LOC-3

Start, Stop, Run-Jog, Fwd/Rev, Manual/Auto, Speed Adjust

LOC-4

Remote Operator Control Station (separate NEMA 12 enclosure)

 

 

Start, Stop, Run-Jog, Speed Adjust

ROC-1

Start, Stop, Run-Jog, Manual/Auto Speed Adjust

ROC-2

Start, Stop, Run-Jog, Fwd/Rev, Speed Adjust

ROC-3

Start, Stop, Run-Jog, Fwd/Rev, Manual/Auto Speed Adjust

ROC-4

Note 1: Jog (J2) cannot be supplied with any Preset Speed Option
Note 2: Preset Speed Options do not include the External Speed Potentiometers.
Note 3: Some modification combinations are mutually exclusive,
others may be obtained by custom engineering by Polyspede.

 

AC Drives
Volts/Hertz, Sensorless
Vector and Flux Vector
drives ranging
from 1/4 to 200 HP.

DC Drives
Non Regenerative
and Regenerative
drives from 1/6
to 500 HP.
AC Motors
AC motors from Baldor,
AO Smith, Lincoln,
Marathon and Reliance.
DC Motors
DC motors from Baldor
and AO Smith.


Maps & Directions
Systems
Quote
Support
Literature