SC Series
The SC control is flexible, cost effective
way to implement compact mini systems for manual
or automatic motion control.
It combines the popular OC2 control design with standard
options and logic circuits.The SC series is available in three basic
types:
BSC
for forward operation without armature contactors
FSC
for forward operation with one armature contactor
RSC
for forward and reverse operation with two armature contactors
and dynamic braking
Ratings:
1/8 - 1 HP
Input:115 VAC
+ 10%, 1Ø, 50/60Hz + 5%
Output: 0-90 VDC armature,
100VDC field
1/4 - 5 HP
Input: 230
VAC + 10%, 1Ø, 50/60Hz + 5%
Output: 0-180 VDC armature,
200VDC field

Overload Capacity:
150% for one minute
Acceleration:
Adjustable from 0.5 to 15 seconds.
Torque
(current) limit:
Adjustable from 50 to 150% of rating.
Minimum
speed:
Adjustable from -5 to 10%
Maximum
speed:
Adjustable from 70 to 110%
IR
Compensation:
Adjustable from 0 to 10% boost.
FEATURES:
*
Short
circuit protection by sub-cycle line fuses.
* Independent, simultaneously operating torque and speed loops
with sharp/smooth transition provide optimum speed regulation
and precise torque limit cut-in regardless of speed setting.
* External torque limit program terminals can be used to set
maximum torque in speed program mode or to program torque
for tension control.
* Low level logic for options interfacing
* Screw type input-output connections
* Dynamic braking
(standard on RSC, optional on FSC)
* Pushbutton start-stop operation
* Adjustable jog (optional)
* Automatic reversing (optional on RSC only)
*
Voltage follower/isolator (optional)
*
Multiple preset speeds (optional)
* NEMA 12 enclosure (optional)
* Speed meter (optional)
* Local operator station (optional)
* Remote operator Station (optional)
* Tachometer feedback (optional)
| SC
Series Model Selection Table |
| HP |
Input |
BSC
Model |
FSC
Model |
RSC
Model |
| 1/8 |
115
VAC |
BSC-12 |
FSC-12 |
RSC-12 |
| 1/6 |
115
VAC |
BSC-16 |
FSC-16 |
RSC-16 |
| 1/4 |
115
VAC |
BSC-25 |
FSC-25 |
RSC-25 |
| 1/4 |
230
VAC |
BSC-26 |
FSC-26 |
RSC-26 |
| 1/3 |
115
VAC |
BSC-33 |
FSC-33 |
RSC-33 |
| 1/3 |
230
VAC |
BSC-34 |
FSC-34 |
RSC-34 |
| 1/2 |
115
VAC |
BSC-50 |
FSC-50 |
RSC-50 |
| 1/2 |
230
VAC |
BSC-51 |
FSC-51 |
RSC-51 |
| 3/4 |
115
VAC |
BSC-75 |
FSC-75 |
RSC-75 |
| 3/4 |
230
VAC |
BSC-76 |
FSC-76 |
RSC-76 |
| 1 |
115
VAC |
BSC-100 |
FSC-100 |
RSC-100 |
| 1 |
230
VAC |
BSC-101 |
FSC-101 |
RSC-101 |
| 1.5 |
230
VAC |
BSC-150 |
FSC-150 |
RSC-150 |
| 2 |
230
VAC |
BSC-200 |
FSC-200 |
RSC-200 |
| 3 |
230
VAC |
BSC-300 |
FSC-300 |
RSC-300 |
| 5 |
230
VAC |
BSC-500 |
FSC-500 |
RSC-500 |
OPTIONS LIST (cost extra)
|
Option
|
Notes
|
Code
|
| Adjustable
Jog See Note I |
Independent
of run speed |
J2
|
| Dynamic
Braking |
Optional
for FSC, standard for RSC |
D
|
|
Automatic
Reversing
|
RSC
only
|
AR
|
|
Tach
Feedback
50 VDC/1000 rpm Tach
(R) when used with RSC
|
1150
rpm motor
|
T(R)l
|
|
1750
rpm motor
|
T(R)2
|
|
|
2400
rpm motor
|
T(R)3
|
|
|
External
Signal Controls
with isolators for input
signal.
|
1-5
mA DC
|
S11
|
|
4-20
mA DC
|
S12
|
|
|
10-50
mA DC
|
S13
|
|
|
0-6
VDC
|
S21
|
|
|
0-90
VDC (armature)
|
S31
|
|
|
0-180
VDC (armature
|
S32
|
|
|
0-240
VDC (armature)
|
S33
|
|
|
0-500
VDC (armature)
|
S34
|
|
|
0-20
VDC (tach)
|
S41
|
|
|
0-40
VDC (tach)
|
S42
|
|
|
0-80
VDC (tach)
|
S43
|
|
|
0-150
VDC (tach)
|
S44
|
|
|
Tach
Follower
(no isolator)
|
0-20
VDC
|
TF1
|
|
20-65
VDC or 25-75VAC
|
TF2
|
|
|
65-200
VDC or75-200VAC
|
TF3
|
|
|
Preset
Speeds - See Note 2
|
7
internal
|
PS7
|
|
6
internal, I external
|
PS6
|
|
|
4
internal
|
PS4
|
|
|
3
internal, I external
|
PS3
|
|
|
7
external
|
PSO
|
|
|
10
turn Potentiometer and Dial
|
|
TPD
|
|
NEMA
12 Enclosure
|
with
OFF/ON & Pilot Light
|
N12
|
|
Speed
Meter
|
Installed
on N12 option
|
SMI
|
|
Local
Operator Control Station (installed on N12 option)
|
Start,
Stop, Run-Jog, Speed Adjust
|
LOC-1
|
|
Start,
Stop, Run-Jog, Manual/Auto, Speed Adjust
|
|
LOC-2
|
|
Start,
Stop, Run-Jog, Fwd/Rev, Speed Adjust
|
LOC-3
|
|
|
Start,
Stop, Run-Jog, Fwd/Rev, Manual/Auto, Speed Adjust
|
LOC-4
|
|
|
Remote
Operator Control Station (separate NEMA 12 enclosure)
|
Start,
Stop, Run-Jog, Speed Adjust
|
ROC-1
|
|
Start,
Stop, Run-Jog, Manual/Auto Speed Adjust
|
ROC-2
|
|
|
Start,
Stop, Run-Jog, Fwd/Rev, Speed Adjust
|
ROC-3
|
|
|
Start,
Stop, Run-Jog, Fwd/Rev,
Manual/Auto Speed Adjust
|
ROC-4
|
|
Note
1: Jog (J2)
cannot be supplied with any Preset Speed Option
Note 2: Preset Speed Options do not include the External Speed
Potentiometers.
Note 3: Some modification combinations are mutually exclusive,