Polyspede's 
PHASE CONVERTER drive 'SPEDESTAR' series  was launched in August 2007.
It's available to operate up to 60 HP,  Three Phase electric motors from Single Phase power source.

Click Here for Flyer 


Polyspede's 
Digital DC drive 'SPEDESTER'  was launched in January 2005. It's available in Regenerative version up to 300HP and Non-Regenerative version up to 350HP.

Click Here for Flyer 

 
 


PC1 Series

Rated Input Voltage:
200 - 240VAC, +10%,
SINGLE Phase (1Ø)
50/60Hz + 5%.


Rated Output Voltage:
200 - 240V + 10%,
THREE Phase (3Ø)
According to supply voltage.
5 - 50 HP

 

PC1 Series
Model Selection Table
HP Model kW kVA Output (A)
5 PC1-50 3.75 6.1 17
7.5 PC1-75 5.5 9.4 25
10 PC1-100 7.5 12.4 33
15 PC1-150 11 17.2 45
20 PC1-200 15 22.9 60
25 PC1-250 18.5 27.8 73
30 PC1-300 22.5 34.5 91
40 PC1-400 30 41.7 110
50 PC1-500 37.5 57 150

Control Method:
Sine-wave pulse width modulation (SPWM) control
V/F and Sensorless Vector Control

Output Frequency Range:
0.1 - 600 Hz

Overload Protection:
150% of rated current for 1 minute/10 minutes
Ta <=40, 200% of rated current for 2 seconds


Output Frequency Resolution:
0.01 Hz

PWM Carrier Frequency:
1kHz -18kHz Adjustable (Some models are limited)

Acceleration/Deceleration Time:
0.1-6000 seconds  (2 Independent settings for Accel/Decel Time)

Torque Characteristics:
Including the auto-torque, auto-slip compensation; starting torque can be 150% at 1.0Hz

Stall Prevention Level:
10 to 250%, Setting of Rated Current. Setting range 0.1-600Hz while stop.

DC Braking:
DC Braking Current Level: 0 to 125% of rated output current. DC Braking time: 0 to 60 seconds. Start-Point for DC Braking: 0.1-600Hz both when start up and stop.

Braking Torque:
Approx. 20%. Dynamic Brake chopper built-in in Frame code:PC1-a and PC1-B. Others can be built-in as an option. All models can connect to external Dynamic Brake Unit (DBU).

Frequency Setting-

Keypad:
By a rotary encoder (setting resolution 0.01Hz/step).

External signal:
0 ~ +10VDC((Input impedance 20kΩ), -10 ~ +10VDC((Input impedance 10kΩ),4 ~20mA dc ((Input impedance 250Ω),Multi-Function Inputs 1 ~ 6 (15 Steps Jog, up/down), PLC run, RS-485 Interface MODBUS protocol . If this characteristic is not convenient, contact Polyspede.

Operation Setting-

Keypad:

Set by RUN, STOP and JOG

External signal:
FWD, REV, MI1 to MI6 can be combined to offer various modes of operation, RS-485 serial interface  MODBUS protocol

Multi-Function Input Signals -
Multi-step selection 0 to 15, first to second accel/decel switches, accel/decel inhibit, EF Input, Emergency Stop, auxiliary motor control is invalid, ACI/AVI/AUI speed command selection,, Reset, PLC Run, Jog, Up/Down command, Sink/Source selection

Multi-Function Output Signal -
Drive Operating, Frequency Attained, Non-zero, Base Block, Fault Indication, Local/Remote indication, PLC Operation indication, and Auxiliary Motor Output

Analog Output Signal:
Analog signal output.  Proportional to output frequency, output current, voltage, frequency command or motor's speed. 

Fault Indication:
The output will be activated when faults occur (1 Relay contact point RA, RB, RC. or 2 Open-collector output)


Other Functions:

PID feedback control, automatic voltage regulation, Momentary Power Loss restart, S-Curve, External Fault, Fault Reset, Auto Restart, Fault Records, Prevention, Frequency Limits, Fan & Pump Control, Parameter Lock/Reset, Auto Tuning, Reverse Inhibition, Over-Voltage/ Over-Current Stall Prevention, automatic energy-saving, DC Braking, Speed Search during Start-up, PLC, MODBUS Communication,

Protection:
Overcurrent, overvoltage, undervoltage, overload, extreme high/low temperature, CPU error, memory error, ground fault detection at startup, internal communication error, Electronic thermal, CT error

Removable Keypad:
Eight Function keys:
Access R un, Stop, Reset/ Digit Shift, Forward/ Reverse run, Display mode, Keypad Enable, Programming data and Jog operation.
One 360 degree Rotary Encoder:  Sets the parameter number and changes the numerical data 
One 6 digits 7 segment display:  Display the Setting frequency/actual operation frequency, Output current/Voltage, User defined unit,
Six LED Display for status indication: Display the Drive run/stop status, forward/Reverse run status, Keypad enable, and Frequency command source

Environment:

Ambient Operating:
-10 ~ +40(Non-Condensing and not frozen).
Storage: -20 ~ +60
Humidity:
Below 90RH (Non-Condensing)
Vibration:
Below 20Hz: 1G, above 20Hz: 0.6G
Location:
Altitude 1,000 m or lower, keep away from corrosive gasses, liquid and dust


Options:
Dynamic braking unit, braking resistor, & AC reactor

.

 

AC Drives
Volts/Hertz, Sensorless
Vector and Flux Vector
drives ranging
from 1/4 to 200 HP.

DC Drives
Non Regenerative
and Regenerative
drives from 1/6
to 500 HP.
AC Motors
AC motors from Baldor,
AO Smith, Lincoln,
Marathon and Reliance.
DC Motors
DC motors from Baldor
and AO Smith.


Maps & Directions
Systems
Quote
Support
Literature