Our legendary OC2 series has been revamped with improved features and was launched in June 2002.
Click Here for Flyer 

OC2B is an open/closed chassis motor control that has been designed as building block solid state regulated power unit. OC2B uses state of the art control circuitry which can be used by itself, by wiring in the provided speed potentiometer as a straightforward speed regulated control or can be incorporated into much more sophisticated system designs contactor operation, external speed programming and tach feedback etc.


Options Groups

Basic Optional Functions

Dynamic Braking (D)

(Standard on RSC, Optional on FSC Not available on BSC) A factory installed option. An electronic lock out prevents re-start until the motor has stopped. The braking registor is sized for one stop per minute from top speed at rated horsepower with external load inertia not exceeding the armature inertia. Consult the factory if a more severe duty cycle is required.

Adjustable Jog (J2)

(Optional on BSC, FSC, RSC) jog is specified only when the Preset Speeds option is not specified. (The Preset Speeds option includes provision for jog operation)

A factory or field installed option, consisting of a printed circuit board assembly with a JOG SPEED potentiometer, a relay and an LED indicator. The Potentiometer adjusts jog speed from 0 to 100% of rated speed. The LED lights when the potentiometer is active. The relay disconnects any other speed input and feeds the JOG position and the FORWARD (or REVERSE) switch is held activated.

Auto Reversing (AR)

(RSC only) A factory or field modification of the standard reversing circuit. (See the RSC description and the SC block diagram) The modification consists only of cutting a printed circuit board jumper. This causes reversing upon momentary switch activation, as opposed to the standard reversing which requires sustained activation until the motor stops. AR is especially useful in limit switch reversing applications.

Tachometer Feedback
Group

Tachometer feedback improves speed regulation, extends the regulated speed range and reduces sensitivity to line voltage variations ambient temperature changes and motor heating.

Tachometer feedback is a factory-installed option/modification. It consists of disabling the armature voltage feedback circuit and providing the tachometer scaling net-work for a 50V/1000 RPM motor - mounted tachometer. When used with reversing drives, (RSC) a printed circuit board mounted tachometer-reversing relay is included.

Tachometer Feedback Group
For 50V/1000 RPM DC Tachometers
Select one only
Option Code Drive Group Motor Base Speed
T1 BSC, FSC 1150 RPM
T2 BSC, FSC 1750 RPM
T3 BSC, FSC 2400 RPM
TR1 RSC 1150 RPM
TR2 RSC 1750 RPM
TR3 RSC 2400 RPM
*Consult the factory for other base speeds or for tachometer voltage gradients other than 50 V/1000 rpm.

Preset Speeds Group

The Preset Speeds option group provides a means to select and program multiple built in preset speed pots and or external signals and to assign operational functions to the selections. A speed pot or speed input can be selected by three methods.

Method 1 : By maintained normally open remote switches

Method 2 : By operator controlled switches in combination with program
jumbers

Method 3 : By a combination of Methods 1 and 2.

The preset speeds option is a factory or field installed printed circuit board assembly that can be set up or programmed in the field or in the factory. The option board contains lights to indicate which speed pot is active; also legends to assign names and identify functions of the program. See the programming strip in the photograph above.

Field setup in Method 1 consists of removing terminal block shorting straps as remote switches are connected.

Field setup in Method 2 consists of adding program jumpers to assign the name and function of each pot or speed input. These names (and appropriate combinations) can be assigned.

FWD JOG
REV
MAN
RUN AUTO

Field setup in Method 3 results in such pot names as

FWD
FWD SPD NO.2
SPD NO.1 Etc.



With the FWD portion set up by Method 2 and SPD NO set up by remote switches.

Preset Speeds Group
Use on BSC, FSC or RSC
Compatible with all options except Jog (J2)
(Jog can be programmed in Preset Speeds)
Option Code Description
PS7
Seven (7) printed circuit board mounted speed pots
PS6
Seven (7) speeds - 6 set by board mounted pots, and
One controlled by an External Signal Control option
PS4
Four (4) PCB mounted speed pots
PS3
Four (4) speeds - 3 set by board mounted pots and one
controlled by an External Signal Control option.
PS0
Seven (7) speeds set by remote speed pots or signals not
included in this option. A terminal block for connection of the remote pot wipers or signals is provided.

 

 

AC Drives
Volts/Hertz, Sensorless
Vector and Flux Vector
drives ranging
from 1/4 to 200 HP.

DC Drives
Non Regenerative
and Regenerative
drives from 1/6
to 500 HP.
AC Motors
AC motors from Baldor,
AO Smith, Lincoln,
Marathon and Reliance.
DC Motors
DC motors from Baldor
and AO Smith.


Maps & Directions
Systems
Quote
Support