HP series
The HP series of DC motor
controls provide accurate speed regulation, repeatable speed
settings and large power capacity in a compact package.
Designed for high stress industrial applications, the HP operates
on three phase 230 or 460 VAC input. A full-wave, six SCR
output power section delivers six pulses for every AC input
cycle. This provides for smooth and cool motor operation,
even in high torque, low speed applications.
The HP series is available in
three basic types:
- BHP for forward operation
without armature contactors
- FHP for forward operation
with one armature contactor
- RHP for forward and reverse
operation with two armature contactors and dynamic braking
Ratings:
3 - 20
HP
Input:
230
VAC + 10%, 3Ř, 50/60Hz + 5%
Output: 0-240 VDC armature,
150VDC field
(240 VDC field optional)
Ratings:
3 - 40 HP
Input: 460
VAC + 10%, 3Ř, 50/60Hz + 5%
Output: 0-500 VDC armature,
300VDC field

Overload
Capacity:
150% for one minute
Instantaneous
Overcurrent trip:
Preset for 260% of rated current
Acceleration
/ Deceleration:
Independently adjustable from 0.6 to 28 seconds.
Torque
(current) limit:
Adjustable from 0 to 200% of rating.
Minimum
speed:
Adjustable from 0 to 10% of rated output voltage.
Maximum
speed:
Adjustable from 75 to 105% of rated output voltage.
IR
Compensation:
Adjustable from 0 to 10% boost.
Speed
Regulation:
(percent of base speed with
95% load change)
+ 1.0% with armature feedback
+ 0.1% with tachometer feedback.
Speed
Command Input:
4 - 20 milliamp or 0-6 VDC.
Tachometer
feedback input:
175 or 2500 rpm motors with a 50 VDC/1000 rpm tachometer
standard, other ranges available.
Dimensions
(open chassis):
3 - 10 HP, 230 VAC:
14" (W) x 14" (H) x 5-5/8" (D)
15 - 20 HP, 230 VAC:
14" (W) x 15-1/2" (H) x 5-5/8" (D)
5 - 25 HP, 460 VAC:
14" (W) x 14" (H) x 7" (D)
30 - 40 HP, 460 VAC:
14" (W) x 15-1/2" (H) x 7" (D)
Weight:
open chasis: 20
lbs
|
HP
Series Model Selection Table
|
| HP |
Input |
BHP
Model |
FHP
Model |
RHP
Model |
| 3 |
230
VAC |
BHP-30 |
FHP-30 |
RHP-30 |
| 3 |
460
VAC |
BHP-31 |
FHP-31 |
RHP-31 |
| 5 |
230
VAC |
BHP-50 |
FHP-50 |
RHP-50 |
| 5 |
460
VAC |
BHP-51 |
FHP-51 |
RHP-51 |
| 7.5 |
230
VAC |
BHP-75 |
FHP-75 |
RHP-75 |
| 7.5 |
460
VAC |
BHP-76 |
FHP-76 |
RHP-76 |
| 10 |
230
VAC |
BHP-100 |
FHP-100 |
RHP-100 |
| 10 |
460
VAC |
BHP-101 |
FHP-101 |
RHP-101 |
| 15 |
230
VAC |
BHP-150 |
FHP-150 |
RHP-150 |
| 15 |
460
VAC |
BHP-151 |
FHP-151 |
RHP-151 |
| 20 |
230
VAC |
BHP-200 |
FHP-200 |
RHP-200 |
| 20 |
460
VAC |
BHP-201 |
FHP-201 |
RHP-201 |
| 25 |
460
VAC |
BHP-251 |
FHP-251 |
RHP-251 |
| 30 |
460
VAC |
BHP-301 |
FHP-301 |
RHP-301 |
| 40 |
460
VAC |
BHP-401 |
FHP-401 |
RHP-401 |
FEATURES:
*
Current sensing
shunt provides a low-voltage signal proportional to the armature
current for current monitoring circuits
* Power-on timer ensures
power supply stability before startup by delaying startup
by 200 milliseconds
* Optional automatic
reversing remembers a reverse command and causes the motor
to dynamically brake to zero speed, then reverse without an
additional start command
* CMOS logic provides
high noise immunity and low power consumption
* Built-in signal
isolation permits connecting the speed pot control common
to earth ground
* Digital ramp generator
prevents phase mismatch between lines and eliminates ramp
balance adjustments
* Line isolation provides
impedance-isolated armature feedback and transformer-isolated
shunt feedback signals
* Reed relays reduce
electrical noise
* Latching network
allows use of standard momentary contact push buttons for
operator commands
* 50 or 60 Hz input
selection
* Contactor timing
and interlocks ensure zero current switching in models with
contactors, extending contactor life
* LED indicators show
phase loss protection, low line voltage protection, torque
limit and forward or reverse operation
* Phase-insensitive
AC input
* Control transformer
(460 VAC models only)
* Independently adjustable
acceleration and deceleration ramps
* Instantaneous overcurrent
trip with LED fault indicator
* Anti-plug protection
prevents start-up or reversal of the drive until the motor
armature reaches zero speed
* Tachometer feedback
input for 1750 or 2500 rpm motors with a 50 VDC/1000 rpm tach
* Remote/Local torque
programming by jumper selection
* Speed command input
of 4-20 milliamp or 0-6 VDC
* Standard options
to meet most requirements
Options (cost
extra)
|
Option
|
Notes
|
Code
|
| Field
Economizing
| FHP
and RHP only
| FE |
| Inverse
Timed Shutdown
| Electronic
motor overload
| ITS |
| Change
to 240V Field
| (230V
Units Only)
| 240 |
| Speed
Indicating Meter (Shipped Loose)
| 3
1/2 inch Analog
| SML |
| Speed
Indicating Meter (Door Mounted)
| Analog,
Installed on NEMA 12 option
| SME |
| External
Torque Programming
|
| ETP |
| Adjustable
Jog - Note 2
|
| J2 |
| Automatic
Reversing (RHP only)
| Allows
motor to reverse without a stop command
| AR |
| Change
to 50Hz Operation
|
| 50 |
| Preset
Speeds - Note 3
| 0
Internal, 7 External
| PS0 |
| 3
Internal, 1 External
| PS3 |
| 4
Internal, 0 External
| PS4 |
| 6
Internal, 1 External
| PS6 |
| 7
Internal, 0 External |
PS7 |
| Armature
Voltage Follower
| 0-90
VDC
| VF1 |
| 0-180
VDC
| VF1 |
| 0-240
VDC
| VF1 |
| 0-500
VDC
| VF2
|
| External
Signal Follower
| 1-5
mA DC
| SF1 |
| 4-20
mA DC
| SF2 |
| 10-50
mA DC
| SF3 |
| 0-6
VDC
| SF4 |
| 0-10
VDC |
SF4 |
| Tachometer
Follower
| 0-20
VDC
| TF1 |
| 0-65
VDC
| TF2 |
| 0-200
VCD
| TF3 |
| 0-75
VAC
| TF2 |
| 0-230
VAC |
TF3 |
Tachometer
Feedback - Note 1
(50 VDC/1000 rpm)
| (BHP,
FHP) 1750 rpm
| T2 |
| (BHP,
FHP) 2400 rpm
| T3 |
| (RHP)
1750 rpm
| TR2 |
| (RHP)
2400 rpm |
TR3 |
Dynamic
Braking (Standard on RHP)
| 3-10hp
(230V)
| D1 |
| 15-20hp
(230V)
| D2 |
| 3-15hp
(460V)
| D3 |
| 20-40hp
(460V) |
D4 |
| NEMA
12 Enclosure
| 3-10hp
(230V) & 3-20hp (460V)
| E1 |
| 15hp
(230V) & 25-30hp (460V)
| E2 |
| 20hp
(230V)
| E3 |
| 40hp
(460V) |
E4 |
| Circuit
Breaker (Door Mounted)
| 3-10hp
(230V) & 3-20hp (460V)
| CB1 |
| 15hp
(230V) & 25-30hp (460V)
| CB2 |
| 20hp
(230V)
| CB3 |
| 40hp
(460V) |
CB4 |
Local
Operator Control Station
(Installed on NEMA 12 Option)
| Start,
Stop, Run/Jog, Speed Adjust
| LOC-1 |
| Start,
Stop, Run/Jog, Manual/Auto, Speed Adjust
| LOC-2 |
| Start,
Stop, Run/Jog, Fwd/Rev, Speed Adjust
| LOC-3 |
| Start,
Stop, Run/Jog, Manual/Auto, Fwd/Rev, Speed Adjust |
LOC-4 |
Remote
Operator Control Station
(Separate NEMA 12 Enclosure)
| Start,
Stop, Run/Jog, Speed Adjust
| ROC-1 |
| Start,
Stop, Run/Jog, Manual/Auto, Speed Adjust
| ROC-2 |
| Start,
Stop, Run/Jog, Fwd/Rev, Speed Adjust
| ROC-3 |
| Start,
Stop, Run/Jog, Manual/Auto, Fwd/Rev, Speed Adjust |
ROC-4 |
| Field
Loss Protection
| 150
VDC field
| FL1 |
| 240
VDC field
| FL2 |
| 300
VDC field |
FL3 |
Note 1:
Tachometer feedback option does not include a tachometer generator.
Note 2:
Jog speed option cannot be supplied with any preset speed option.
Note 3:
Preset speed options do not include the external speed potentiometers.
Note 4:
Some pre-designed option combinations are mutually exclusive.
Others may be obtained by custom engineering from Polyspede.
|