Ratings:
3 - 20
HP
Input:
230
VAC + 10%, 3Ø, 50/60Hz + 5%
Output: 0-240 VDC armature,
150VDC field
(240 VDC field optional)
Ratings:
3 - 40 HP
Input: 460
VAC + 10%, 3Ø, 50/60Hz + 5%
Output: 0-500 VDC armature,
300VDC field

Overload
Capacity:
150% for one minute
Instantaneous
Overcurrent trip:
Preset for 260% of rated current
Acceleration
/ Deceleration:
Independently adjustable from 0.6 to 28 seconds.
Torque
(current) limit:
Adjustable from 0 to 200% of rating.
Minimum
speed:
Adjustable from 0 to 10% of rated output voltage.
Maximum
speed:
Adjustable from 75 to 105% of rated output voltage.
IR
Compensation:
Adjustable from 0 to 10% boost.
Speed
Regulation:
(percent of base speed with
95% load change)
+ 1.0% with armature feedback
+ 0.1% with tachometer feedback.
Speed
Command Input:
4 - 20 milliamp or 0-6 VDC.
Tachometer
feedback input:
175 or 2500 rpm motors with a 50 VDC/1000 rpm tachometer
standard, other ranges available.
Dimensions
(open chassis):
3 - 10 HP, 230 VAC:
14" (W) x 14" (H) x 5-5/8" (D)
15 - 20 HP, 230 VAC:
14" (W) x 15-1/2" (H) x 5-5/8" (D)
5 - 25 HP, 460 VAC:
14" (W) x 14" (H) x 7" (D)
30 - 40 HP, 460 VAC:
14" (W) x 15-1/2" (H) x 7" (D)
Weight:
open chasis: 20
lbs
|
HP
Series Model Selection Table
|
| HP |
Input |
BHP
Model |
FHP
Model |
RHP
Model |
| 3 |
230
VAC |
BHP-30 |
FHP-30 |
RHP-30 |
| 3 |
460
VAC |
BHP-31 |
FHP-31 |
RHP-31 |
| 5 |
230
VAC |
BHP-50 |
FHP-50 |
RHP-50 |
| 5 |
460
VAC |
BHP-51 |
FHP-51 |
RHP-51 |
| 7.5 |
230
VAC |
BHP-75 |
FHP-75 |
RHP-75 |
| 7.5 |
460
VAC |
BHP-76 |
FHP-76 |
RHP-76 |
| 10 |
230
VAC |
BHP-100 |
FHP-100 |
RHP-100 |
| 10 |
460
VAC |
BHP-101 |
FHP-101 |
RHP-101 |
| 15 |
230
VAC |
BHP-150 |
FHP-150 |
RHP-150 |
| 15 |
460
VAC |
BHP-151 |
FHP-151 |
RHP-151 |
| 20 |
230
VAC |
BHP-200 |
FHP-200 |
RHP-200 |
| 20 |
460
VAC |
BHP-201 |
FHP-201 |
RHP-201 |
| 25 |
460
VAC |
BHP-251 |
FHP-251 |
RHP-251 |
| 30 |
460
VAC |
BHP-301 |
FHP-301 |
RHP-301 |
| 40 |
460
VAC |
BHP-401 |
FHP-401 |
RHP-401 |
FEATURES:
*
Current sensing
shunt provides a low-voltage signal proportional to the armature
current for current monitoring circuits
* Power-on timer ensures
power supply stability before startup by delaying startup
by 200 milliseconds
* Optional automatic
reversing remembers a reverse command and causes the motor
to dynamically brake to zero speed, then reverse without an
additional start command
* CMOS logic provides
high noise immunity and low power consumption
* Built-in signal
isolation permits connecting the speed pot control common
to earth ground
* Digital ramp generator
prevents phase mismatch between lines and eliminates ramp
balance adjustments
* Line isolation provides
impedance-isolated armature feedback and transformer-isolated
shunt feedback signals
* Reed relays reduce
electrical noise
* Latching network
allows use of standard momentary contact push buttons for
operator commands
* 50 or 60 Hz input
selection
* Contactor timing
and interlocks ensure zero current switching in models with
contactors, extending contactor life
* LED indicators show
phase loss protection, low line voltage protection, torque
limit and forward or reverse operation
* Phase-insensitive
AC input
* Control transformer
(460 VAC models only)
* Independently adjustable
acceleration and deceleration ramps
* Instantaneous overcurrent
trip with LED fault indicator
* Anti-plug protection
prevents start-up or reversal of the drive until the motor
armature reaches zero speed
* Tachometer feedback
input for 1750 or 2500 rpm motors with a 50 VDC/1000 rpm tach
* Remote/Local torque
programming by jumper selection
* Speed command input
of 4-20 milliamp or 0-6 VDC
* Standard options
to meet most requirements
Options (cost
extra)
|
Option
|
Notes
|
Code
|
| Field
Economizing
| FHP
and RHP only
| FE |
| Inverse
Timed Shutdown
| Electronic
motor overload
| ITS |
| Change
to 240V Field
| (230V
Units Only)
| 240 |
| Speed
Indicating Meter (Shipped Loose)
| 3
1/2 inch Analog
| SML |
| Speed
Indicating Meter (Door Mounted)
| Analog,
Installed on NEMA 12 option
| SME |
| External
Torque Programming
|
| ETP |
| Adjustable
Jog - Note 2
|
| J2 |
| Automatic
Reversing (RHP only)
| Allows
motor to reverse without a stop command
| AR |
| Change
to 50Hz Operation
|
| 50 |
| Preset
Speeds - Note 3
| 0
Internal, 7 External
| PS0 |
| 3
Internal, 1 External
| PS3 |
| 4
Internal, 0 External
| PS4 |
| 6
Internal, 1 External
| PS6 |
| 7
Internal, 0 External |
PS7 |
| Armature
Voltage Follower
| 0-90
VDC
| VF1 |
| 0-180
VDC
| VF1 |
| 0-240
VDC
| VF1 |
| 0-500
VDC
| VF2
|
| External
Signal Follower
| 1-5
mA DC
| SF1 |
| 4-20
mA DC
| SF2 |
| 10-50
mA DC
| SF3 |
| 0-6
VDC
| SF4 |
| 0-10
VDC |
SF4 |
| Tachometer
Follower
| 0-20
VDC
| TF1 |
| 0-65
VDC
| TF2 |
| 0-200
VCD
| TF3 |
| 0-75
VAC
| TF2 |
| 0-230
VAC |
TF3 |
Tachometer
Feedback - Note 1
(50 VDC/1000 rpm)
| (BHP,
FHP) 1750 rpm
| T2 |
| (BHP,
FHP) 2400 rpm
| T3 |
| (RHP)
1750 rpm
| TR2 |
| (RHP)
2400 rpm |
TR3 |
Dynamic
Braking (Standard on RHP)
| 3-10hp
(230V)
| D1 |
| 15-20hp
(230V)
| D2 |
| 3-15hp
(460V)
| D3 |
| 20-40hp
(460V) |
D4 |
| NEMA
12 Enclosure
| 3-10hp
(230V) & 3-20hp (460V)
| E1 |
| 15hp
(230V) & 25-30hp (460V)
| E2 |
| 20hp
(230V)
| E3 |
| 40hp
(460V) |
E4 |
| Circuit
Breaker (Door Mounted)
| 3-10hp
(230V) & 3-20hp (460V)
| CB1 |
| 15hp
(230V) & 25-30hp (460V)
| CB2 |
| 20hp
(230V)
| CB3 |
| 40hp
(460V) |
CB4 |
Local
Operator Control Station
(Installed on NEMA 12 Option)
| Start,
Stop, Run/Jog, Speed Adjust
| LOC-1 |
| Start,
Stop, Run/Jog, Manual/Auto, Speed Adjust
| LOC-2 |
| Start,
Stop, Run/Jog, Fwd/Rev, Speed Adjust
| LOC-3 |
| Start,
Stop, Run/Jog, Manual/Auto, Fwd/Rev, Speed Adjust |
LOC-4 |
Remote
Operator Control Station
(Separate NEMA 12 Enclosure)
| Start,
Stop, Run/Jog, Speed Adjust
| ROC-1 |
| Start,
Stop, Run/Jog, Manual/Auto, Speed Adjust
| ROC-2 |
| Start,
Stop, Run/Jog, Fwd/Rev, Speed Adjust
| ROC-3 |
| Start,
Stop, Run/Jog, Manual/Auto, Fwd/Rev, Speed Adjust |
ROC-4 |
| Field
Loss Protection
| 150
VDC field
| FL1 |
| 240
VDC field
| FL2 |
| 300
VDC field |
FL3 |
Note 1:
Tachometer feedback option
does not include a tachometer generator.
Note 2:
Jog speed option cannot be supplied with any preset
speed option.
Note 3:
Preset speed options do not include the external speed potentiometers.
Note 4:
Some pre-designed option combinations are mutually exclusive.
Others may be obtained by custom engineering from Polyspede.
|